Charging unit ZP– 11


Charging unit ZP– 11 is designed to ensure the charge and discharge of a portable battery VHF radio station R-005U in field and stationary conditions.
Types of rechargeable batteries:
– Nickel-cadmium batteries (BA-005U) with a nominal voltage of 24 V and a capacity of 5 A ∙ h;
– lithium-ion batteries 28,8 Li-ion-18 / 65-7,8A rated voltage 28.8 V and capacity
7.8 A ∙ h
Modes of operation of the ZP-11:
– charge;
– discharge – only for nickel-cadmium batteries.
The “charge” mode for the ZP-11 turns on automatically after connecting the batteries to the charging unit.
The design of the ZP-11 consists of a lower compartment and a cover. In the closed position, the lid is fixed with locks. On the cover of the ZP-11 is fixed a handle for carrying the product.

Parameter Value
Amount of charging current: 1,8 ± 0,2 А
Maximum charge time: 7 h.
The power supply of the charger is carried out from the on-board DC network with a nominal voltage value: 27 V. (18-36 V.)
The discharge for the ZP-11 is carried out on the load resistance for each of the two sections of the battery: 14.1 ohms ± 10%
The time of transfer of the charger to the working state from the storage state in conserved form does not exceed: 30 min.
The readiness of the charger to work, taking into account the preparation time for work, is no more than: 15 min.
Mean time to failure  – not less: 10000 h.
Average recovery time – no more than: 30 min.
Operation mode of the charger: all-day continuous use.
The charger is operated in climatic conditions:
    ambient temperature: from minus 10º to plus 50º С
    relative humidity: no more than 98% at a temperature of 25º С
    atmosphere pressure: from 450 to 850 mm hg.art.
Weight ZP-11 with a lid and a power cable without battery no more: 6,5 kg.
Overall dimensions of ZP-11 no more: 220х300х200 mm.