Charging units S-1001 and S-1002


Charging units S-1001 and S-1002 are designed to ensure the charge and discharge of the battery pack (hereinafter – BP) of a VHF portable 2 W R-002PP radio in field and stationary conditions.
BP types that charge:
– lithium-ion BP VH550, VH551 with a nominal voltage of 7.2 V and a capacity of 2.6, 3.9 A • hours.
The charge of the BP begins automatically after it is installed in the charger. During charging, the “CHARGE” indicator is lit. When the charge is complete, the indicator goes out.
The charge of BP is performed by direct current.

Parameter Значення
The number of simultaneously charged battery packs: 1 pc.(S-1001)
2 pc.(S-1002)
Power consumption – no more than: 15 W.(S-1001)
30 W.(S-1002)
Maximum charge voltage: 8,3±0,2 V.
Amount of charging current: 1,0±0,3 А.
Maximum charge time: 7 h.
The power supply of the charger is carried out from the on-board DC network with a nominal voltage value: 12/27 V. (10-36 V.)
The time of transfer of the charger to the working state from the storage state in conserved form does not exceed: 30 min.
The readiness of the charger to work, taking into account the preparation time for work, is no more than: 15 min.
The average time between failures is not less than: 10000 h.
Average recovery time – no more than: 30 min.
Operation mode of the charger: all-day continuous use.
The charger is operated in climatic conditions:
   ambient temperature: from minus 10º to plus 50º С
    relative humidity: no more than 98% at a temperature of 25º С
    atmosphere pressure: from 450 to 850 mm hg.art.
Mass of the charger without power cable and without BP no more: 1,6 kg.(C-1001)
2,0 kg.(C-1002)
Overall dimensions of the charger without BP no more than: 175х115х105 mm.(C-1001) 275х115х105 mm.(C-1002)