Container for field hardware control and communication (shelter) K-01


The container is designed to provide installation, transportation and operation of military equipment in communication systems of all levels of command and control of the Armed Forces of Ukraine.
The container provides for installation both on the wheelbase and in the form of a stationary communication facility in field conditions.
The container is not adapted to accommodate personnel during movement.
The structure of the container includes equipment mounted inside the container, technological and auxiliary equipment, heating system, ventilation system, electrical equipment, tools and accessories, a set of mounting parts.
The container is designed to meet the requirements of mobile and stationary systems.
The container is a frame construction, multi-layered panels for the floor, roof and walls, made of steel corrugated, with a filling of rigid foamed polyurethane 40 mm thick.
The container is equipped with systems of guaranteed power supply, heating, ventilation, air conditioning and lighting.
The system of guaranteed power supply (SGEP) is designed to provide power: communications and control equipment, heating, ventilation and lighting systems.
The container is powered from the main, backup or emergency power sources.
The main power source is a single-phase stationary AC power supply with a nominal voltage of 220 V (from 187 to 242 V) and a frequency of 50 Hz.
Separate external cable entries are provided in the shelter to transmit open and secret information. Shelter is designed for round the clock continuous operation.

Parameter Value
Power supply – AC mains with rated voltage: 220 V.
Input voltage tolerance: plus 10% minus 15% (from 187 to 242 V)
Permissible limits of output voltage: from 21 to 28 V
Electromagnetic shielding – not worse: 30 dB – in the frequency range
from 150 to 1000 kHz
60 dB – in the frequency range
from 1 MHz to 1 GHz
Maximum load on the container floor: 300 kg/m2
Maximum load on the roof of the container: 200 kg/m2
The container is operated in climatic conditions:
    ambient temperature: from minus 30º to plus 50º С
    relative humidity: no more than 98% at a temperature of 25º С
   atmosphere pressure: from 450 to 850 mm hg. art.
Container weight: 2500 kg.
Overall dimensions of the container: 3900х2650х2300 mm.